<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-15 19-33-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.30 MHz 5/5, 75 dBuV YLESUOMI
Pilot RDS Phase Difference
7.1 kHz 3.7 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 65 kHz 18980 1,6333
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,0 dBr 3,02 dBr 4,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLESUOMI" 6203 1 (News) 1 0 1 1 19:33, 15.10.2024
RT
-
AF EON
95.6, 97.3, 98.4, 98.6, 98.9, 99.2, 102.5 MHz 6202, 6207, 6205, 6201
FM Scope Max at: 65 kHz MIN: 10 kHz % above 76 kHz: 1,6333 Acquired: 2024/10/15 19.32.07 Total samples: 18980 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,2 dBr MIN: 2,0 dBr AVE: 3,02 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2024/10/15 19.32.07) 19.18 19.20 19.22 19.24 19.26 19.28 19.30 19.32 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]